SightLine Applications Command, Control, and Script API  v3.3
List of all members
SLASetTelemetryDestination_t Struct Reference

Description

Configure the Ethernet IP address of clients for telemetry.

typedef struct {
u8 mode;
u8 cameraID;
u32be ipAddr;
u16 udpDestinationPort;
u8 flags;
u8 reserved;

Up to four (4) IP addresses may be added to the list. All telemetry enabled by SLACoordinateReportingMode_t will be sent to each receiver.

Also sent in response to SLAGetParameters_t().
NOTE: Telemetry output is not available in Demo Mode.

See also
SLACoordinateReportingMode_t for the types of Telemetry output that are available.

Message ID 0x64

Byte Offset Name Description
4modeFunction
Value Description
0 Reserved
1 Add an IP address as telemetry output destination
2 Remove an IP address from receiving telemetry output
3 Remove all IP addresses from telemetry output list
4-15 Reserved
5cameraIDReserved
6-9ipAddrIP address of receiver to be added/removed; 3000 only: 0 = send telemetry to serial port
10-11udpDestinationPortDestination port – data is sent to this port on the receiver, 0 = Reserved
12flags
Bit Description
0 0 = Do not save this packet destination
1 = save packet destination when parameter file is saved and restore when loaded
1 0 = Do not apply camera ID (instead send actual camera index in telemetry packets)
1 = send cameraID in telemetry packets (1500 only)
2-7 Reserved
13reservedReserved